Summary of Contents for Kruzer

Page 1: ......

Page 2: ...Do not use any chemicals for cleaning and or for any other purposes 3 Wipe the screen and the shaft dry with a soft non scratch cloth Protect the detector against impacts during normal use For shippin...

Page 3: ...RGROUND DEPTH E U D PINPOINT TARGET DEPTH LARGE OR SHALLOW TARGETS FALSE SIGNALS AND REASONS MAGNETIC MINERALIZATION INDICATOR ROCKS AND SEARCHING IN ROCKY TERRAINS TRACKING AND EFFECTS OF ROCKS METAL...

Page 4: ...located on the rear pressed down and clicking the pin in any of the holes Secure by tightening the twist lock 4 Wind the search coil cable on the shaft without stretching too much Then plug the conne...

Page 5: ...g menu options and changing the device settings 6 On Off button 7 OPTIONS button to access extra settings 8 Ground balance button 9 Wired headphones charger optional battery pack input IMPORTANT When...

Page 6: ...harging adapter other than the one supplied with your device Operating with a Powerbank You can also power and charge the battery with a powerbank To do this just insert one of the ends of the cable s...

Page 7: ...internal battery remove the optional battery case cable and turn the device off and on again Otherwise the device will continue to display the Lo battery warning BATTERY WARNINGS Do not expose the de...

Page 8: ...ID upon target detection the ground balance whole number value during ground balancing GB and the estimated target depth PP in the pinpoint mode In addition the numeric value of any setting selected...

Page 9: ...t of the shaft so that you are standing in an upright position your arm is relaxed and the search coil is approximately 5cm 2 above the ground It is important to keep the search coil parallel to the g...

Page 10: ...on t want to detect ferrous metals with 00 05 ID in the 2 TONE mode you can set the DISC to 5 8 If you are detecting in a very trashy area and the device is getting too many iron signals instead of DI...

Page 11: ...e display GB The device continues to ground balance and produce a beep sound as long as you keep the GB button pushed down and pump the coil In order to ensure that the ground balance is proper ground...

Page 12: ...eeping it parallel to the ground If the sound gets higher when lifting off the search coil above the ground the ground balance value is too low in other words the effect from the ground is negative an...

Page 13: ...target If the sound attenuates too much or is lost after a few swings it means that the device has produced a signal for the different ground structure or a stone NOTE It is recommended that you use t...

Page 14: ...cases where the iSAT value is set high the device may not be able to ground balance automatically In such a case first lower the iSAT and after ground balancing switch it back to its previous positio...

Page 15: ...with you during your searches Coins searched throughout the world are made of different metals and in different sizes in different geographical locations and historical eras Therefore in order to lea...

Page 16: ...y 1 second DISC is set to 03 as a default value You can modify this value according to the ID of the targets you don t want to detect In this mode the device produces a low tone for ferrous targets wi...

Page 17: ...tive due to high ionization and cause effects similar to that of iron in detectors These effects may make it impossible to search for metals with a standard detector Existence of an iron elimination f...

Page 18: ...s highly mineralized causing the device to overload decrease the gain until the Overload message disappears from the screen Gain in General Search Mode GEN In the GEN mode gain setting causes an incre...

Page 19: ...5 stability will increase but depth will be reduced and vice versa Above 15 though both depth and noise will increase NOTCH NOTCH is the ability of the device to discriminate single or multiple Target...

Page 20: ...one volume between n1 n5 n5 is the maximum level and the iron volume will be reduced as you go down but it cannot be silenced completely NOTCH adjustment applies to the selected search mode only The c...

Page 21: ...the operating frequency of the device you may need to re adjust the Tone Break points according to the IDs you will get in the new frequency TONE Allows you to change the target audio response tones...

Page 22: ...levels The device will start at level 6 It is recommended that iSAT should be increased in high mineralization and decreased in low mineralization iSAT in Discrimination Modes It is used to eliminate...

Page 23: ...en it is switched to 0 vibration feature is completely disabled If the vibration is at 01 level the device provides long vibra tion signals and at 05 it provides short vibration signals The magnitude...

Page 24: ...F5 using the plus and the minus buttons IMPORTANT Frequency shift may impair performance Therefore it is suggested that you do not shift the frequency unless it is necessary FREQ Setting in the multi...

Page 25: ...ect FD SAVE on screen Two dashes will be displayed on screen Push the right button When SA is displayed press the SELECT button once You will see lines rotating in the middle of the screen When the sa...

Page 26: ...g this feature Pinpoint is to find the center or the exact location of a detected target Kruzer is a motion detector In other words you are required to move the search coil over the target or the targ...

Page 27: ...n inches instead of cms please do the following While the device is off press and hold the SELECT and OPTIONS buttons simultaneously and turn the device on In will be displayed To switch back to cms y...

Page 28: ...nductivity and magnetic properties of the ground are too intense Operation of the device over such ground is made possible by selecting the best operating mode and frequency multi Kruzer as well as us...

Page 29: ...d ID when it passes over a hot rock because the effect of the rock will be different than the ground s If you swing the search coil over the rock tracking will automatically adjust the setting and the...

Page 30: ...to give high IDs then the chances of missing the signals of small metals underneath will be high as well IMPORTANT When searching in fields with hot rocks using the E U D feature page 23 is recommende...

Page 31: ...surface or a very large object The device reverts back to normal operation if you lift the coil up If the alarm and the message continue along a long line you may be over a long metal such as a pipe I...

Page 32: ...dio Tone Break Notch Filter Ground Balance Pinpoint Frequency Shift Vibration Gain Setting Target ID Search Coil Display Backlight Weight Length Battery Warranty VLF Kruzer 14kHz Multi Kruzer 5kHz 14k...

Page 33: ...und 1982 40 67 72 Two Pounds 2006 48 71 77 Fi y Pence 2008 23 35 44 Twenty Pence 1982 24 38 51 Two Pence 1988 70 86 90 Penny 1918 40 66 71 1938 Shilling 47 69 75 1921 Half Crown 70 84 89 1928 Six Penc...

Page 34: ......

Page 35: ......

Page 36: ......

Reviews: