Thermo Scientific APEX User’s Guide
Page 263
Reject-Confirm Fault
The faults may occur when the reject-confirm function has been enabled and the
confirmation signal fails to return within the prescribed time limit.
Problem
Solution
The reject device has failed.
Check the action of your reject device and make
sure it is working properly. Check the reject-confirm
switch. Increase the reject-confirm time using the
detector’s reject-confirm function.
The reject device acted too
slowly.
The switch has failed on your
reject-confirm device.
Excessive Rejects Fault
Problem
Solution
This fault only occurs when
the excess-reject-fault
function has been activated,
and indicates that and
excessive number of rejects
have occurred within the
specified time window.
Press Clear Fault. Please note that this fault may be
caused by excessive contamination in the product—
so please examine the rejected product to see
whether it is heavily contaminated.
Photo-Reject Fault
This type of fault only occurs in conveyor applications using a photo eye.
Problem
Solution
This fault occurs when the
photo-reject function has
been enabled, contaminated
product has been detected,
but the photo eye did not see
the product.
Check the alignment of the photo eye. Make sure
the product is breaking the beam, and check for
reasons for false triggering such as metal in the belt.
Perform a complete test of the detector including the
reject device.
Photo-Eye Blocked Fault
This type of fault only occurs in conveyor applications using a photo eye.
Problem
Solution
This fault indicates that the
photo eye has been blocked
for an excessive amount of
time.
Check the photo-eye for proper operation and
alignment.
Summary of Contents for APEX 100
Page 1: ...Thermo Scientific APEX Metal Detector User s Guide REC 4248 Rev K Part number 085381 English ...
Page 10: ...Page 10 Thermo Scientific APEX User s Guide ...
Page 78: ...Page 78 Thermo Scientific APEX User s Guide ...
Page 110: ...Page 110 Thermo Scientific APEX User s Guide ...
Page 258: ...Page 258 Thermo Scientific APEX User s Guide ...
Page 270: ...Page 270 Thermo Scientific APEX User s Guide ...
Page 282: ...Page 282 Thermo Scientific APEX User s Guide ...
Page 310: ...Page 310 Thermo Scientific APEX User s Guide ...
Page 319: ...Thermo Scientific APEX User s Guide Page 319 Appendix A Modbus Communications Card ...
Page 320: ...Page 320 Thermo Scientific APEX User s Guide ...
Page 324: ...Page 324 Thermo Scientific APEX User s Guide ...
Page 340: ...Page 340 Thermo Scientific APEX User s Guide ...
Page 367: ...Thermo Scientific APEX User s Guide Page 367 Appendix B IntelliTrack XR ...
Page 368: ...Page 368 Thermo Scientific APEX User s Guide ...
Page 402: ...Page 402 Thermo Scientific APEX User s Guide ...
Page 404: ...This page intentionally left blank ...
Page 414: ...This page intentionally left blank ...
Page 430: ......
Page 431: ......
Page 432: ......
Page 433: ......
Page 434: ......
Page 435: ......
Page 436: ......
Page 437: ......
Page 438: ......
Page 439: ......
Page 440: ......
Page 441: ......
Page 442: ......