background image

 
 
 

R1

 

OPERATING INSTRUCTIONS 

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

NEWFORCE 

by 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Newforce R1

Page 1: ...R1 OPERATING INSTRUCTIONS NEWFORCE by...

Page 2: ...select this program The R1 is now ready to use SEARCHING Keep the search head at a constant height above the ground i e do not allow the search head to swing higher at the right and left edges of you...

Page 3: ...ATURES Twin Microprocessor control system Large Backlit Liquid Crystal Display CASSY Computer Aided Search SYstem RADAR Real Time Ground Radar Display High speed target analyser ID Target Pin Point Au...

Page 4: ...3 R 1 A Battery Compartment B Upper Stem Handle Grips C Din Plug Socket D Stem Connecting Nut E Cable F Lower Stem G Cable Slots H Search Head Fastener A B C D E F H G...

Page 5: ...r do not fully remove these from the cover and remove the cover Inside is the battery holder Lift out the holder and detach the connector if it is already fitted Load it with the eight batteries ensur...

Page 6: ...ttery Monitor GROUND RADAR SIMULATOR This unique continuously scrolling RADAR is a view of the signal received by the R1 circuit It can be used as an additional tool to analyse any signals It is also...

Page 7: ...ll 11 Cartwheel 1d 19 Hammered Silver Sixpence 10 New 10p Coin 9 THE CONTROLS AND WHAT THEY DO ON OFF VOLUME This rotary control is used to turn the unit on and off and adjust the volume level of the...

Page 8: ...U SCROLL control acts as a conventional Discrimination control Turning the control clockwise increases the discrimination level This is indicated by the black squares under the I D numbers on the disp...

Page 9: ...ithin the entire range Once selected a flashing block cursor will appear under the 0 at the left hand edge of the display Pressing the ENTER button will toggle the block at the current cursor position...

Page 10: ...kground tone This is only audible with Silent Search turned off As soon as Tune is selected then Silent Search will be turned OFF so that the background tone will be heard Once the desired level has b...

Page 11: ...BACK Silent search will suppress the background tone set by the TUNE setting In this mode audio will only be heard if there is buried object The rest of the time the audio will be silent Use the MENU...

Page 12: ...are stored separately and retrieved automatically at turn on Once Store or Recall is selected rotate the MENU SCROLL control to highlight the Program to be stored or recalled and then press the ENTER...

Page 13: ...e off so when you turn on the R1 you are presented with a short cut to the easy to use manufacturer defined programs of COIN INLAND for general purpose searching on most sites i e those not affected b...

Page 14: ...SCROLL control and then pressing the ENTER button when satisfied this will store the setting BRIGHTNESS This option sets the brightness level of the backlight In normal daylight the backlight is not...

Page 15: ...h conditions Adjust the ground setting as described above FREQUENCY DISCRIM DISPLAY LOW SENSITIVITY GROUND ADJ MIDDLE AUDIO FREQUENCY HIGH PROGRAMS BATTERY SET UP BACK This can be used to change the o...

Page 16: ...oth signals are maximum is the position of the target Dig carefully to avoid damaging your find Target position Second Sweep First Sweep Detection Range Your R1 is a top performance detector but adver...

Page 17: ...al coming from the detector Each time a signal is heard listen for any peculiar characteristics it may have determine over how large an area you get a detector signal and try to outline the object bef...

Page 18: ...5kHz 714Hz nominal Transmit frequency 6 097kHz 6 250kHz 6 410kHz Search Coils 25cm concentric 15cm 2D Detection Ranges Typical in air performance Motion mode Hammered 6d 20cm 1 coin 30cm old 10p 32cm...

Page 19: ...T ON MOTION OFF MOTION ON SILent SEARCH OFF ON MODE ANALOG DIGITAL PROGRAMS GRouND TYPE INLAND BEACH OPTIONS DEFAULT LAST RECALL COIN INLAND PROGRAM ALL METAL PROGRAM COIN BEACH PROGRAM USER PROGRAM 1...

Page 20: ...r The C Scope battery charger is designed to charge the rechargeable pack safely and efficiently CHARGING BATTERIES A battery charge socket is provided for use with the C Scope battery charger see Acc...

Page 21: ...y carry money The answers are not Roman sites nor are they associated with mystic treasure stories of crocks of gold Rather they are unassuming undramatic places like public footpaths and ancient righ...

Page 22: ...f the ground Sweeping the coil from side to side in a straight line in front of you Keep the coil at a constant height as you sweep from side to side Move the head at a rate of 0 5 metre per second Th...

Page 23: ...cient monument unless permission has been obtained from the Historic Buildings and Ancient Monument Commission for England or the Secretary of State for the Environment in Scotland and Wales 8 Remembe...

Page 24: ...until the transmission stops Intermittent Sound from Speaker a This could be due to poor battery connections Ensure that they are tight and the batteries are securely clipped into place b Loose search...

Page 25: ...please do not hesitate to phone our Customer Service Department on 44 0 1233 629181 or e mail info cscope co uk Before returning a detector for repair to C Scope ensure you have done the following a...

Page 26: ......

Page 27: ...erformance may be impaired by unusually strong electromagnetic fields Kingsnorth Technology Park Wotton Road Ashford Kent TN23 6LN United Kingdom Telephone 44 0 1233 629181 Fax 44 0 1233 645897 email...