Alarm Codes
73
54
Test Mode Time-out
A diagnostic mode timed out, does not affect unit
performance.
X
55
Check Engine Speeds
Engine speed out of spec, check RPM, monitor box temp,
repair as required.
X
56
Evap Fan Low Speed
Unit operating with no low speed evaporator fan, repair as
required (RC units only).
X
57
Evap Fan High Speed
Unit operating with no high speed evaporator fan, repair as
required (RC units only).
X
58
Cond Fan Low Speed
Unit operating with no low speed condenser fan, repair as
required (RC units only).
X
59
Cond Fan High Speed
Unit operating with no high speed condenser fan, repair as
required (RC units only).
X
Table of Alarm Codes
*Alarms with an asterisk (*) can exist with Alarm Code 84. The alarm can clear automatically if condition does not reoccur.
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code
Description
Corrective Action
Level Of
Action
Ok
T
o
Run
Ch
eck
S
hut
Dow
n
Alarm Codes
73
54
Test Mode Time-out
A diagnostic mode timed out, does not affect unit
performance.
X
55
Check Engine Speeds
Engine speed out of spec, check RPM, monitor box temp,
repair as required.
X
56
Evap Fan Low Speed
Unit operating with no low speed evaporator fan, repair as
required (RC units only).
X
57
Evap Fan High Speed
Unit operating with no high speed evaporator fan, repair as
required (RC units only).
X
58
Cond Fan Low Speed
Unit operating with no low speed condenser fan, repair as
required (RC units only).
X
59
Cond Fan High Speed
Unit operating with no high speed condenser fan, repair as
required (RC units only).
X
Table of Alarm Codes
*Alarms with an asterisk (*) can exist with Alarm Code 84. The alarm can clear automatically if condition does not reoccur.
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code
Description
Corrective Action
Level Of
Action
Ok
T
o
Run
Ch
eck
S
hut
Dow
n
Summary of Contents for SB-200TG
Page 1: ...Operator s Manual SB 200TG Operator s Manual SB 200TG TK 53598 2 OP Rev 0 02 07...
Page 7: ...6 Table of Contents 6...
Page 11: ...10 Introduction 10...
Page 21: ...20 EPA Emission Control System Warranty Statement 20...
Page 43: ...42 TG VI Controller Description 42...
Page 45: ...44 Remote Status Light Optional 44...
Page 83: ...82 Alarm Codes 82...
Page 103: ...102 Warranty 102...
Page 117: ...116 Serial Number Locations 116...