Alarm Codes
77
84
Restart Null
Temporary shutdown resulting from other alarm codes.
Refer to detailed explanation at start of chapter.
X
85
Forced Unit Operation
Temporary forced operation resulting from other alarm
codes. Refer to detailed explanation at start of chapter.
X
86 Discharge
Press
Transducer
Unit operating with reduced performance, monitor box temp,
repair as required.
X
87
Suction Press Transducer
Unit operating with reduced performance, monitor box temp,
repair as required.
X
88
Unassigned
89
Electronic Throttling Valve Circuit
If Check Alarm, unit operating with reduced performance,
monitor box temp, repair as required. If Shutdown Alarm,
ETV or refrigeration system failure, repair immediately.
X
X
Table of Alarm Codes
*Alarms with an asterisk (*) can exist with Alarm Code 84. The alarm can clear automatically if condition does not reoccur.
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code
Description
Corrective Action
Level Of
Action
Ok
T
o
Run
Ch
eck
S
hut
Dow
n
Alarm Codes
77
84
Restart Null
Temporary shutdown resulting from other alarm codes.
Refer to detailed explanation at start of chapter.
X
85
Forced Unit Operation
Temporary forced operation resulting from other alarm
codes. Refer to detailed explanation at start of chapter.
X
86 Discharge
Press
Transducer
Unit operating with reduced performance, monitor box temp,
repair as required.
X
87
Suction Press Transducer
Unit operating with reduced performance, monitor box temp,
repair as required.
X
88
Unassigned
89
Electronic Throttling Valve Circuit
If Check Alarm, unit operating with reduced performance,
monitor box temp, repair as required. If Shutdown Alarm,
ETV or refrigeration system failure, repair immediately.
X
X
Table of Alarm Codes
*Alarms with an asterisk (*) can exist with Alarm Code 84. The alarm can clear automatically if condition does not reoccur.
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code
Description
Corrective Action
Level Of
Action
Ok
T
o
Run
Ch
eck
S
hut
Dow
n
Summary of Contents for SB-200TG
Page 1: ...Operator s Manual SB 200TG Operator s Manual SB 200TG TK 53598 2 OP Rev 0 02 07...
Page 7: ...6 Table of Contents 6...
Page 11: ...10 Introduction 10...
Page 21: ...20 EPA Emission Control System Warranty Statement 20...
Page 43: ...42 TG VI Controller Description 42...
Page 45: ...44 Remote Status Light Optional 44...
Page 83: ...82 Alarm Codes 82...
Page 103: ...102 Warranty 102...
Page 117: ...116 Serial Number Locations 116...