Alarm Codes
67
08
Remote Return Air Sensor
Remote zone controls on coil sensor, monitor box temp,
repair as required.
X
09*
High Evaporator Temperature
Unit shut down to prevent damage, repair immediately.
X
10*
High Discharge Pressure or
Temp
Unit shut down to prevent damage, clear and retry, if
reoccurs repair immediately.
X
11
Unit Controlling on Alternate
Sensor
Secondary alarm related to Alarm Code 3 or 4, monitor box
temp, repair as required.
X
12
Sensor Shutdown
Unit shut down to prevent damage, repair immediately.
X
13
Check Sensor Calibration
Monitor box temp with independent thermometer, repair as
required.
X
14
Defrost Terminated by Time
Clear alarm, repair after delivery.
X
Table of Alarm Codes
*Alarms with an asterisk (*) can exist with Alarm Code 84. The alarm can clear automatically if condition does not reoccur.
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code
Description
Corrective Action
Level Of
Action
Ok
T
o
Run
Ch
eck
S
hut
Dow
n
Alarm Codes
67
08
Remote Return Air Sensor
Remote zone controls on coil sensor, monitor box temp,
repair as required.
X
09*
High Evaporator Temperature
Unit shut down to prevent damage, repair immediately.
X
10*
High Discharge Pressure or
Temp
Unit shut down to prevent damage, clear and retry, if
reoccurs repair immediately.
X
11
Unit Controlling on Alternate
Sensor
Secondary alarm related to Alarm Code 3 or 4, monitor box
temp, repair as required.
X
12
Sensor Shutdown
Unit shut down to prevent damage, repair immediately.
X
13
Check Sensor Calibration
Monitor box temp with independent thermometer, repair as
required.
X
14
Defrost Terminated by Time
Clear alarm, repair after delivery.
X
Table of Alarm Codes
*Alarms with an asterisk (*) can exist with Alarm Code 84. The alarm can clear automatically if condition does not reoccur.
NOTE: Not all alarm codes are available with all microprocessor controllers or all revisions of software.
Code
Description
Corrective Action
Level Of
Action
Ok
T
o
Run
Ch
eck
S
hut
Dow
n
Summary of Contents for SB-200TG
Page 1: ...Operator s Manual SB 200TG Operator s Manual SB 200TG TK 53598 2 OP Rev 0 02 07...
Page 7: ...6 Table of Contents 6...
Page 11: ...10 Introduction 10...
Page 21: ...20 EPA Emission Control System Warranty Statement 20...
Page 43: ...42 TG VI Controller Description 42...
Page 45: ...44 Remote Status Light Optional 44...
Page 83: ...82 Alarm Codes 82...
Page 103: ...102 Warranty 102...
Page 117: ...116 Serial Number Locations 116...