Installation and Operation
Installation Procedures
2-5
Themis Computer
•
Screw B—
Remove the eight screws marked “B” in
Figure 2-2
on
page 2-4, which will free the air-flow diverter so that it can be removed
from the system. After the air-flow diverter has been removed, the memory
module slots will be exposed (see
Figure 2-3
).
2.
If a module is already seated in the slot you have selected for installation,
remove it by gently pressing down and outward on the latches at both ends of
the slot (see
Figure 2-4
on page 2-6), then pulling the old module directly up
from the slot until it is free of the connector (see
Figure 2-4
on page 2-6).
Figure 2-3.
Memory Module Slot Locations
P2 DIMM 1A
P2 DIMM 2A
P2 DIMM 3A
P2 DIMM 1B
P2 DIMM 2B
P2 DIMM 3B
P2 DIMM 1C
P2 DIMM 2C
P2 DIMM 3C
P1 DIMM 1A
P1 DIMM 2A
P1 DIMM 3A
P1 DIMM 1B
P1 DIMM 2B
P1 DIMM 3B
P1 DIMM 1C
P1 DIMM 2C
P1 DIMM 3C
Branch 0
Branch 1
Branch 2
Branch 0
Branch 1
Branch 2