RES-32XR3/FIO Installation Manual
2-12
Themis Computer
3.
When the fan is removed, its 4-wire connector will automatically disconnect
from the chassis. Insert the replacement fan carefully into the empty fan slot
until it is flush with the second fan. The 4-wire connector will automatically
engage its counterpart connector successfully.
2.1.7
Power Supply
Each 750-watt load-sharing (N+1 redundant) power supply can be hot-swapped
while the system is still on and operational.
2.1.7.1 Removing a Power Supply
Perform the following steps to remove a power supply:
1.
Remove the two captive Phillips screws holding the power supply locking
bracket to the chassis. Store the bracket for later use (see
A
in
Figure 2-11
).
2.
Put the right index finger on the power supply extraction handle and the right
thumb on the bottom side of the power supply locking lever.
3.
Squeeze the locking lever toward the pull handle and firmly pull the power
supply from the chassis.