3-11
Themis Computer
BIOS Setup Utility
Advanced Setup Configurations
operations in parallel.
•
Sparing
- A preset threshold of correctable errors is used to trigger fail-over.
The spare memory is put online and used as active memory in place of the
failed memory.
3.3.4.6 Demand Scrubbing
A memory error-correction scheme where the Processor writes corrected data back
into the memory block from where it was read by the Processor. The options are
Enabled
and Disabled.
3.3.4.7 Patrol Scrubbing
A memory error-correction scheme that works in the background looking for and
correcting resident errors. The options are
Enabled
and Disabled.
3.3.4.8 Throttling - Closed Loop / Throttling - Open Loop
Throttling improves reliability and reduces power in the processor by automatic
voltage control during processor idle states. Available options are
Disabled
and
Enabled. If Enabled, the following items will appear:
Hysteresis Temperature (Closed Loop only)
Temperature Hysteresis is the temperature lag (in degrees Celsius) after the set
DIMM temperature threshold is reached before Closed Loop Throttling begins. The
options are
Disabled
, 1.5°C, 3.0°C, and 6.0°C.
Guardband Temperature (Closed Loop only)
This is the temperature which applies to the DIMM temperature threshold. Each step
is in 0.5°C increment. The default is
[006]
. Press “+” or “-” on your keyboard to
change this value.
Inlet Temperature
This is the temperature detected at the chassis inlet. Each step is in 0.5°C increment.
The default is
[070]
. Press “+” or “-” on your keyboard to change this value.
Summary of Contents for RES-32XR3/FIO
Page 20: ...xviii Themis Computer RES 32XR3 FIO Installation Manual...
Page 46: ...1 20 Themis Computer RES 32XR3 FIO Installation Manual...
Page 64: ...2 18 Themis Computer RES 32XR3 FIO Installation Manual...
Page 112: ...Themis Computer RES 32XR3 FIO Installation Manual B 4...
Page 136: ...E 4 Themis Computer RES 32XR3 FIO Installation Manual...
Page 140: ...RES 32XR3 FIO Installation Manual Index 4 Themis Computer...