Advisory
DCC: Single-Shot-Mode Operation May End Prematurely
Revisions Affected
0, A, B
Details
In single-shot mode, DCCSTATUS[DONE] or DCCSTATUS[ERROR] may be prematurely
set. When this occurs, DCC results are invalid.
Workaround
Any of the following conditions ends DCC operation prematurely. TI recommends
rerunning DCC if
any
of the below conditions are met.
• DCCSTATUS[DONE] = 1 and (DCCCNT1 > 0 or DCCCNT0 > 0 or DCCVALID0 > 0)
• DCCSTATUS[ERROR] = 1 and DCCCNT1 > 0 and DCCVALID0 > 0
Silicon Revision B Usage Notes and Advisories
20
TMS320F28004x Real-Time MCUs Silicon Errata
Silicon Revisions B, A, 0
SPRZ439G – JANUARY 2017 – REVISED AUGUST 2022
Copyright © 2022 Texas Instruments Incorporated