Commands Listed in Alphabetical Order
Group
Status
Syntax
*STB?
Related Commands
,
Returns
<NR1>
Examples
*STB?
96
shows that the SBR contains the binary value 01100000.
SYSTem:ERRor? (Query Only)
This command queries the error code and error information of the power supply
and returns both values. (See Table 3-6 on page 3-9.)
Group
System
Syntax
SYSTem:ERRor?
Returns
<NR1>,<error_text>
<error_text> ::= <string>
where
<string>
is a description of the error.
Examples
SYSTEM:ERROR?
might return
110
, which means No Input Command to parse.
SYSTem:KEY
This command can produce the same effect as pressing one of the front-panel
buttons. The instrument must be in local mode in order for this command to
simulate a front-panel button press.
Group
System
Syntax
SYSTem:KEY <NR1>
SYSTem:KEY?