Commands Listed in Alphabetical Order
Arguments
None.
Examples
SYSTEM:REMOTE
SYSTem:RWLock (No Query Form)
If the power supply is in remote mode, this command locks out the front panel
LOCAL button. This command has no effect if the instrument is in local mode.
Group
System
Syntax
SYSTem:RWLock
Related Commands
,
Arguments
None.
Examples
SYSTEM:RWLOCK
SYSTem:VERSion? (Query Only)
This command returns SCPI version of the instrument.
Group
System
Syntax
SYSTem:VERSion?
Returns
<NR2>
is the software version of the power supply.
Examples
SYSTEM:VERSION?
might return
1991.0
, which is the SCPI version number.
*TRG (No Query Form)
This command generates a trigger event.
PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 Power Supply Programmer Manual
2-45