Status and Events
The Operation Condition Register (OCR).
The Operation Condition Register is
made up of eight bits, which note the occurrence of events as shown here.
Figure 3-4: The Operation Condition Register (OCR)
Table 3-3: OCR bit functions
Bit
Function
7 (MSB)
———— This bit is not used.
6
———— This bit is not used.
5
RUN
Running List.
Indicates that the power supply is
executing a list.
4
TBF
Trace Buffer Full.
This bit is used internally, by
the instrument.
3
CC
Constant Current.
Indicates that the power supply is
in constant current mode and is regulating its output current.
2
CV
Constant Voltage.
Indicates that the power supply is
in constant voltage mode and is regulating its output voltage.
1
WTG
Waiting for Trigger.
Indicates that the power
supply is waiting for a trigger.
0 (LSB)
CAL
Calibrating.
Indicates that the power supply is
calculating a new calibration parameter.
The Operation Event Register (OEVR).
The Operation Event Register has the same
content as the Operation Condition Register.
The Questionable Condition Register (QCR).
The Questionable Condition Register
is made up of eight bits which note the occurrence of
fi
ve types of events as
shown here.
Figure 3-5: The Questionable Condition Register (QCR)
Table 3-4: QCR bit functions
Bit
Function
7 (MSB)
———— This bit is not used.
6
———— This bit is not used.
5
———— This bit is not used.
4
PS
Protection Shutdown.
3
RI
Remote Inhibit.
This bit indicates the state of the
Remote Inhibit input.
PWS4205, PWS4305, PWS4323, PWS4602, and PWS4721 Power Supply Programmer Manual
3-5
Summary of Contents for PWS4205
Page 2: ......
Page 8: ...Preface iv PWS4205 PWS4305 PWS4323 PWS4602 and PWS4721 Power Supply Programmer Manual...
Page 9: ...Getting Started...
Page 10: ......
Page 61: ...Status and Events...
Page 62: ......
Page 75: ...Appendices...
Page 76: ......