Commands Listed in Alphabetical Order
Arguments
<NR1>
is an integer between 2 and 65535. It determines the number of times the
active list will execute.
ONCe
: con
fi
gures the lists to execute once and stop.
REPeat
: con
fi
gures the lists to loop continuously.
Returns
<NR1>
is the number of times the active list is set to execute.
Examples
LIST:COUNT 6
would set the active list to execute 6 times before stopping.
[SOURce:]LIST:CURRent[:LEVel]
This command sets the current for a list step in units of A or mA.
Group
Source
Syntax
[SOURce:]LIST:CURRent[:LEVel] <NR1>,<current>
[SOURce:]LIST:CURRent[:LEVel]?
<NR1>
Related Commands
,
Arguments
<NR1>
is an integer in the range from 1 to 80, , which is a step number in the
active list.
<current>::=<NRf>[<units]
where
<NRf>
is a
fl
exible decimal number used to specify a current setting in the range 0
amperes to the nameplate current rating of the power supply.
<units>::={A|mA}
Returns
<NR2>
is a decimal representing the current setting in amperes for the step
speci
fi
ed in the query.
Examples
LIST:CURR 1, 3A
LIST:CURR? 1
might respond with 3.0000, which indicates the current level
setting for step number 1.