6.2 Control terminals & wiring
R2A R2B R1A R1B R1C
S1
S3
S5
24V AI1
AI2
S(+) S(-) SF1 SG
SF2 COM S2
S4
S6
AGND
10V
AO
Terminal
Symbol
Description
Rating
SF1
Safety Input 1 & SG connection.
Open:Safe stop mode.
Linked : Normal run mode.
Input resistance:4.22kΩ
Input Current:5 to 6.5 mA
Input Voltage:21.6 to 26.4 V
SF2
Safety Input 2 & SG connection..
Open:Safe stop mode.
Linked:Normal run mode.
SG
Common terminal for S1, S2
+24VDC
Table 3. Safety related terminals
6.3 External 24Vdc supply (Connection option).
R2A R2B R1A R1B R1C
S1
S3
S5
24V AI1
AI2
S(+) S(-) SF1 SG
SF2 COM S2
S4
S6
AGND
10V
AO
Safety Terminals. SF1 / SF2 & SG (Common).
Remove the jumper link for external interface
+24V
OV
External power Supply