4-226
22- 10
PM SLV Start Current
Range
【20.0 ~ 200.0】%
22- 11
I/F Mode Start Frequency Switching Point
Range
【1.0 ~ 20.0】%
22- 14
Armature Resistance of PM Motor
Range
【0.001 ~ 30.000】
Ω
22- 15
D-axis Inductance of PM Motor
Range
【0.01 ~ 300.00】
mH
22- 16
Q-axis Inductance of PM Motor
Range
【0.01 ~ 300.00】
mH
22-18
Flux-Weakening Limit
Range
【0 ~ 100】
%
22- 21
PM motor tuning
Range
【0】: PM Motor Tuning is not Active
【1】: Parameter Auto-tune (for PMSLV Tuning)
22- 23
PM SLV acceleration time
Range
【0.1~10.00】 Sec
22- 25
Initial Position Detection of PM Motor
Range
【0】: Disable
【1】: Detected wheb inverter is running
PMSLV Start Current (22-10)
Set torque current at start and the unit is the percentage of motor rated current.
I/F Mode Start Frequency Switching Point (22-11)
This function is for the switching point from open-loop to close-loop in PMSLV mode. The unit is
percentage for rated speed of motor. It recommends that over 5% for 400V and over 10% for 200V.
Armature Resistance of PM Motor (22-14)
Set resistor for each phase of the motor in unit of 0.001Ω. It is set automatically when the motor
auto-tunes (22-21).
D-axis Inductance of PM Motor (22-15)
Set motor
’
s D-axis inductance in unit of 0.001mH. It is set automatically when the motor auto-tunes
(22-21).
Q-axis Inductance of PM Motor (22-16),
Set motor
’
s Q-axis Inductance in unit of 0.001mH. It is set automatically when the motor auto-tunes
(22-21).
Flux-Weakening Limit (22-18)
If the motor
’
s maximum rotation speed (22-05) is set to be higher than the motor
’
s rated rotation
speed (22-04), it will automatically start the flux-weakening control. It is set to limit the maximum
flux-weakening energy and the unit is the percentage of motor rated current.
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......