4-107
Value
Function
Description
Control Mode
Name
LCD Display
V/F SLV PM
SLV
15
External Baseblock
Command (rotation
freely to stop)
Ext. BB
ON:Inverter base interdiction
O
O
O
16 PID control disable
PID Disable
ON:PID control disabled
O
O
O
17 Fault reset (Reset)
Fault Reset
Fault reset
O
O
O
18 Auto Run Mode Enable
ON:Auto run mode enable(06-00)
-
-
-
19
Speed Search (from the
maximum frequency)
Speed Search 1
ON:Search the speed from the maximum
output frequency
O
O
X
20 Energy Saving
Energy saving
ON:Manual energy saving control is
based on the settings of 11-12 and 11-18.
O
X
X
21
Reset PID Integral Value
to Zero
PID I-Reset
ON:PID integral reset
O
O
O
22 Counter Input
Cnt Input
ON:Counter input by digital input
O
O
O
23 Counter Reset
Cnt Reset
ON:Counter reset by digital input
O
O
O
24 PLC Input
PLC Input
ON:PLC input
O
O
O
25
Pulse-In Width Measure
(S3)
Pulse Input-Width
Measure
ON:Switch S3 to pulse-in width measure O
O
O
26
Pulse-In Frequency
Measure (S3)
Pulse Input-Freqency
Measure
ON:Switch S3 to pulse-infrequency
measure
O
O
O
27 Local/Remote Selection Local/Remote
ON:Local mode (via the digital operator)
OFF:Frequency command and operation
command will be determined
according to the setting of
parameter (00-02 and 00-05).
O
O
O
28 Remote Mode Selection Remote Mode Sel
ON:RS-485 communication
OFF:Control circuit terminal
O
O
O
29
Jog Frequency
Selection
JOG Freq sel
ON:RS-485 communication
O
O
O
30 Reserved
Reserved
Reserved
-
-
-
31 Reserved
Reserved
Reserved
-
-
-
32 Reserved
Reserved
Reserved
-
-
-
33 DC Braking
DC Brake Command
ON:Perform DC braking
O
O
O
34
Speed Search 2 (From
The Frequency
Command)
Speed Search 2
ON:Search speed from set frequency
O
O
X
35 Reserved
Reserved
Reserved
-
-
-
36 Reserved
Reserved
Reserved
-
-
-
37 Reserved
Reserved
Reserved
-
-
-
38 Reserved
Reserved
Reserved
-
-
-
39 Reserved
Reserved
Reserved
-
-
-
40
Switching Between
Motor 1/Motor 2
Motor 2 Switch
ON:Start motor 2
O
O
X
41 Reserved
Reserved
Reserved
-
-
-
42 Reserved
Reserved
Reserved
-
-
-
43 Reserved
Reserved
Reserved
-
-
-
44 Reserved
Reserved
Reserved
-
-
-
45 Reserved
Reserved
Reserved
-
-
-
46 Reserved
Reserved
Reserved
-
-
-
47
Reserved
Reserved
Reserved
-
-
-
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......