JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 6.26
6.9.
THERE IS NO HEART RATE SIGNAL
6.9.1.
T
ELEMETRIC RECEIVER
HFU
The machine displays this error if:
1.
electromagnetic noise saturate the HR receiver which does not display any value due to a
specific SW filter which cut every signal, greater than 220 bpm;
2.
the receiver is not working properly;
3.
the receiver is not supplied by the display board.
THERE IS NO HR
SIGNAL
Does the supply v oltage
correctly reach the input to the
receiv er?
Replace the receiv er
2
3
YES
Is the supply v oltage correct at
the output of the display board?
Replace cable CU135
Replace the display board
NO
YES
NO
Carry out the
troubleshooting procedure
"THE TELEMETRIC
SIGNAL IS INCORRECT"
1
Follow the procedure step by step to correctly diagnose the problem. Take particular care with the
checks highlighted by circled numbers, which are described in detail below:
(1)
Carry out the troubleshooting procedure 6.10. “The telemetric hr signal is incorrect”.
(2)
Place the tester probes across pins 1 and 2 of connector HD4 of the HS / cardio receiver
board. The measured value should be +5 Vdc.
(3)
As for step (2) but across pins 1 and 5 of connector CN9 on the display board.