JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 9.14
9.2.4.2.
Reset errors
To clear the error history log in both the low and high kit, scroll using the +/- keys until the LED
display shows:
RESET ERRORS ?
press
ENTER
to clear the error history log, and return to the upper menu level by pressing
CLEAR
for a few seconds.
9.2.4.3.
COM.Fault
This is a counter that display the number of errors in serial communication between the upper and
the lower kit. This counter increase each time a communication fault is detected. Scroll using the
+/- keys until the display shows:
COM.FAULT X
To reset it press
ENTER
, the LED display shows:
RESET COM.FAULT?
press
ENTER
to reset and return to the upper menu level by pressing
CLEAR
for a few seconds.
9.2.4.4.
View Errors
For every error generated by the machine, the error history log records the information in the table
below:
•
Counter;
•
Error Code;
•
Voltage when the error occurred;
•
Current * 10 when the error occurred;
•
Speed km/h when the error occurred.
The correspondence between error codes and descriptions is given in the table below:
Error
code
Error
number
Description
OH
1
Overheating of the heat sinks of the AT drive and of the PFC.
OC
2
Overcurrent, even if only transient, on the inverter output.
UU
3
Undervoltage condition, due to an even transient drop in line voltage.
OU 4
Overvoltage.
PE 6
EEPROM error. Is generated when there is an error detected in the data
stored on the EEprom.
EdC1
7
Elevation motor encoder error.
OtM
9
AC motor thermal cutout open.
Oli 10
Inverter overload caused by a DC current exceeding, for the maximum
allowed time (I
2
t), the maximum permissible threshold for the inverter.
OLm 11
Motor overload caused by a DC current exceeding, for the maximum
allowed time (I
2
t), the maximum permissible threshold for the motor in
question.