Page 6.11
6.5.
AT DRIVER ERROR
When the AT driver detects an error, it stops and interrupts the power supply to the tread belt and
elevation motor. An error code identifying the fault condition is saved in the error history log. In
addition, it sends an error status signal to the display board via the serial link. Upon receiving this
error signal, the display board halts the exercise and shows the “THE EQUIPMENT IS
BLOCKED” message on the display.
The errors logged by the inverter can also be viewed as described in paragraph 9.2.4. “Errors log”.
The following table shows the correspondence between the numbers and codes:
Error
code
Error
number
Description
OH
1
Overheating of the heat sinks of the AT drive and of the PFC.
OC
2
Overcurrent, even if only transient, on the inverter output.
UU
3
Undervoltage condition, due to an even transient drop in line voltage.
OU 4
Overvoltage.
PE 6
EEPROM error. Is generated when there is an error detected in the data
stored on the EEprom.
EdC1
7
Elevation motor encoder error.
OtM
9
AC motor thermal cutout open.
Oli 10
Inverter overload caused by a DC current exceeding, for the maximum
allowed time (I
2
t), the maximum permissible threshold for the inverter.
OLm 11
Motor overload caused by a DC current exceeding, for the maximum
allowed time (I
2
t), the maximum permissible threshold for the motor in
question.
OLr
12
Braking resistor overload.
Ot 13
Over-torque due to an even momentary overload of the inverter. Is
generated when the torque output of the motor exceeds a pre-established
limit for a pre-established time.
OCH 16
HW
overcurrent.
MST 17
Motor lockout which occurs, operating in closed loop mode with the
encoder active, if the inverter fails to reach the target speed even after
attempting to reduce the reference frequency.
EM 19
Emergency. Is generated when the AT drive receives a software
emergency signal that is not accompanied by a hardware emergency
signal.
SHC 23
Short Circuit. Is generated in the event of a short circuit between a motor
phase and earth.