![Technogym JOG EXCITE Service Maintenance Manual Download Page 104](http://html1.mh-extra.com/html/technogym/jog-excite/jog-excite_service-maintenance-manual_1070258104.webp)
JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 9.10
DEFAULT SETTING ?
press
ENTER
to load the default parameter values, and return to the upper menu level by pressing
CLEAR
for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.
9.2.1.4.
Table of configuration parameters
Parameter Description
Range
Default value
Par
01
Default speed for Quick Start workout.
[Km/h*10]
0 - 300
8
Par 02
Default acceleration and deceleration for tread
belt motor. [Km/h*100/sec]
0 - 3000
100
Par 03
Default zero reference position for tread-belt
incline. [*2]
-10 - +40
0
Par 04
PID proportional gain. [*100]
0 - 9999
7
Par 05
PID Integral gain. [*100]
0 - 9999
150
Par 06
Ramp Type
0 - 100
0
Par 07
Error status on DC motor encoder
0 - 1
0
Par 08
Serial communication timeout [10*msec]
0 - 255
0
Par 09
DC motor encoder error timeout. [msec]
0 - 255
15
Par 10
FREE
-
0
Par 11
Driving roller diameter. [mm]
0 - 1000
74
Par 12
Pulley ratio
0 - 9000
211
Par 13
Error status on AC motor encoder
0 - 1
0
9.2.2.
U
P
D
OWN SETTINGS
This function allows access to the parameters in the UpDown table which define the number of
encoder pulses that correspond to different machine incline positions. To access this menu, when
the LED display shows:
UPDOWN SETTINGS
press
ENTER
. This function is structured as follows: