JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 9.11
UPDOWN SETTINGS
+20%:
-5.0%:
WRITE TO
LOW KIT ?
DEFAULT
SETTINGS ?
READ FROM
LOW KIT ?
.......................
In addition to the 50 configuration parameters, this function also includes the 3 sub-functions
described below:
9.2.2.1.
Read from low kit
To read the parameter values from the low kit memory to view them on the display, scroll using the
+/- keys until the LED display shows
READ FROM LOW KIT ?
press
ENTER
to read the parameters from the low kit, then return to the upper menu level by
pressing
CLEAR
for a few seconds.
9.2.2.2.
Write to low kit
To write the values of the currently displayed parameters to the low kit, scroll using the
+/-
keys
until the LED display shows:
WRITE TO LOW KIT ?
press
ENTER
to write the parameters to the low kit, and return to the upper menu level by pressing
CLEAR
for a few seconds.
9.2.2.3.
Default setting
To load the default parameter values to the display, scroll using the
+/-
keys until the LED display
shows:
DEFAULT SETTING ?
press
ENTER
to load the default parameter values, and return to the upper menu level by pressing
CLEAR
for a few seconds.
To write these parameters to the low kit, use the “Write to low kit” function.