JOG EXCITE: Service & Maintenance Manual - rev. 1.1
Page 9.17
MENU –A–
Par.
AddressDescription
Value Par.
AddressDescription
Value
PID mode (700/900)
1
A-59
1218PID min neg err
50
A-0 1200
PID mode (500)
0
A-100
1219Set Linear speed
0
A-1
1201PID ref sel
5
A-101
1220Set Acc Dec
100
A-2
1202PID fbk sel
4
A-102
1221Set Incline ref
0
A-3
1203PID digital ref
0
A-105
1222Def Linear speed
8
A-4
1204PID activat mode
0
A-106
1223Def Acc Dec
100
A-5
1205PID-Encoder sync
1
A-107
1224Def Incline ref
0
A-6
1206PID err sign rev
0
A-110
1225Pulley Ratio
200
A-7
1207PID Integ init en
0
A-111
1226Roller Diameter
91
A-8
1208PID update time
0
A-50
1209PID Prop gain 1
7
A-115 1227
DCMot EncTimeout
(
AT driver SW
≥
2.07
)
15
A-51
1210PID Int tconst 1
150 A-116
1228Fan command dly
30
A-52
1211PID Deriv gain 1
0
50
A-53
1212PID Prop gain 2
0
A-117 1229ACMot
EncToller
0(OFF)
A-54
1213PID Int tconst 2
9999 A-118
1230Check RunnerBand
10
A-55
1214PID Deriv gain 2
0
A-119
1231Check RunnerSpd
50
A-56
1215PID high limit
80
A-120
1232Curr clamp thr
200
A-57
1216PID low limit
-80 A-121
1233Check RunnerDly
60
A-58
1217PID max pos err
50
MENU –C–
Par.
Address Description
Value Par.
Address Description
Value
C-0 800
Save parameters
0
C-41
805 Save pars to key
0
C-1 801
Recall param
0
C-100
806 Measure stator R
0
C-2 802
Load default
0
C-200
807 Reset AC Flag
0
C-20 803
Alarm clear
0
C-201
808 Reset DC Flag
0
C-40 804
Recall key prog
0
MENU –D–
Par.
Address Description
Value Par.
Address Description
Value
D-0 1
Output frequency
0
D-200
26 An in 1 cnf mon
0
D-1 2
Frequency ref
0
D-201
27 An in 1 monitor
0
D-2 3
Output current
0
D-202
28 An in 1 term mon
0
D-3 4
Output voltage
0
D-210
29 An in 2 cnf mon
0
D-4 5
DC link voltage
400 D-211
30 An in 2 monitor
0
D-5 6
Power factor
100 D-212
31 An in 2 term mon
0
D-6 7
Power [kW]
0
D-220
32 An in 3 cnf mon
0
D-7 8
Output speed
0
D-221
33 An in 3 monitor
0
D-8 9
Speed ref
0
D-222
34 An in 3 term mon
0
D-20 57
Actual speed
0
D-300
35 EncPulse/Sample
0
D-21 58
Actual incline user
0
D-301
36 Encoder freq
0
D-22 59
Actual ENC1 pos
0
D-302
37 Encoder speed
0
D-23 60
Crossed distance
0
D-350
38 Option 1 state
0
D-24 61
Reserved
-
D-351
39 Option 2 state
0
D-25 62
Flag status
0
D-352
40 Par port state
0
D-26 63
Actual ENC2 pos
0
D-400
41 PID reference
0
D-27 64
Actual speed from
Fenc
0 D-401
42 PID
feedback
0
D-30 70
Reserved -
D-402
43 PID
error
0
D-50 10
Heatsink temp
0
D-403
44 PID integr comp
0
D-51 11
Drive OL
0
D-404
45 PID output
0
D-52 12
Motor OL
0
D-800
46 Error 1
0
D-53 13
Brake res OL
0
D-801
47 Error 2
0
D-100 14
Dig inp status
0
D-802
48 Error 3
0
D-101 15
Term inp status
0
D-803
49 Error 4
0
D-102 16
Vir dig inp stat
0
D-950
50 Drive rated cur
100
D-120 17
Exp dig inp stat
0
D-951
51 SW version 1\2
200h
Summary of Contents for JOG EXCITE
Page 1: ...SERVICE MAINTENANCE MANUAL REV 1 1 ...
Page 2: ......
Page 4: ......
Page 20: ...JOG EXCITE Service Maintenance Manual rev 1 1 Page 2 10 Page intentionally left blank ...
Page 68: ...JOG EXCITE Service Maintenance Manual rev 1 1 Page 6 32 Page intentionally left blank ...
Page 125: ......