17
The essential parameters are:
Parameter
Description
Rise Time
This is the time interval in which the valve is open.
The time increment is in 1 µs starting at 80 µs. The
maximum rising time is 1999 µs.
Open Time
This value defines the time in which the valve is
completely open. The value can be varied in steps of
1 µs. The minimum open time is 1 µs and the
maximum open time is 999999 µs.
Fall Time
During this time, the valve is closing and compressing
the media in the nozzle chamber. The time increment
is in 1 µs starting at 80 µs. The maximum falling
time is 1999 µs.
Delay Time
This is the time between two dispense pulses. It is
adjustable in 1 µs.
Percentage Lift (Lift
of Tappet)
This value corresponds to the stroke of the tappet. It is
entered in percent of the maximum stroke (100%).
Pulses
This value corresponds to the number of tappet stroke
per dispensing cycle in dot mode
Heater OFF
This indicate the heater manifold is Off
Heater ON
This indicate the heater manifold is ON (temperature
range is from 0-90 degree C, click on value next to
icon to adjust setting)
After entering the dispensing parameters, touch ‘Save’ icon
to save all the
parameters to the current program location. You can then start your dispensing
process.
Note:
For more detail on how to enter the dispensing parameters,
refer to section 9.5.3.
Table 1 – Essential parameters