4.
Remove the nozzle insert (7) from the nozzle bushing (6).
5.
Use the provided 2mm hex key to remove the two mounting
screws (5) and pull the fluid manifold (4) from the valve body
(1).
Caution:
When remounting the fluid manifold, it’s highly
recommended to torque the two mounting screws to 2.5 – 3.0 lb-
in (0.28 - 0.33 N-m).
Note:
Perform step 6 only if the tappet seal (3) must be replaced or a
thorough cleaning is required. If the manifold is removed for whatever
reasons on a regular basis the tappet seal should also be replaced on a
regular basis.
6.
Remove the tappet seal (3) from the fluid manifold (4) by
inserting the provided tappet seal tool from the fluid manifold’s
outlet hole and slowly push upward on the seal.
•
To install a new tappet seal, carefully place the seal in the
centre hole of the fluid manifold so that the small end of the
seal is facing inward. Make sure that the seal is positioned
evenly and centrally to the hole, then slightly push the seal
with your thumb to engage the seal to the hole.
Caution
: Do
not push the seal all way inside the hole with your thumb.