WARNING:
Make sure the nozzle insert and nozzle bushing are properly installed in the
nozzle unit before starting the calibration process.
Never over-tighten the nozzle unit against the tappet since it can break the
tappet or cause pre-matured wear on both tappet and nozzle insert.
If the yellow circle can’t be moved to or stay inside the green zone, touch
the ‘Accept’ icon to exit and repeat the calibration procedure starting from
Step 1.
Remarks:
•
You can leave the calibration procedure by touching the ‘Accept’
icon.
•
The calibration can only be confirmed by touch the ‘Accept’
icon when the yellow circle is inside the green zone.
•
If you shut down the system and alter nothing mechanically,
you don’t have to perform the calibration procedure again when
switching the system on.
•
The calibration procedure should be done in cleaned dry system
to avoid any influences of the material between nozzle insert
and tappet and to get a consistent dispense result.
•
If the fluid contains particles (fillers), the calibration procedure
performed with fluid is not possible. It must be performed
without fluid.