27
10.
Place all parts in a beaker with proper cleaning solution;
Isopropanol or Acetone can be used for cleaning.
Caution:
Please refer to your facility regulation for proper solvent
usage.
11.
Place the beaker with all parts in an Ultrasonic bath for about
15 – 30 minutes.
Caution:
The nozzle insert can be cleaned and pierced through with
special nozzle insert wire using the Pin Vice. Pay attention to the
nozzle insert diameter and choose the correct nozzle insert wire.
Refer to the pictures below regarding which part to clean with which
cleaning tool.
Make sure to lubricate the tappet assembly and nozzle bushing’s
O-rings with the provided tappet grease prior to re-assembling.