HEATING
6.1 Introduction
The TS9800 Jet Valve with heating system is available for heating high
viscosity fluid.
The heating system also helps to maintain constant temperature. Required
parts:
•
TS9800 Jet Valve with heater
•
Heater Cable
6.2 Safety Instructions
•
Use the Jet Valve with heating system should only be done by
trained staff.
•
Carefully review the material safety data from the dispensing
material.
•
Wear adequate protective clothing before starting to dispense
aggressive fluid.
•
Be cautious that the media you want to dispense is applicable for
use with a heating system.
Warning:
•
When using the Jet Valve with heater, please consult with the
material manufacture for proper operating temperature.
•
Be aware of the exposed surface and fittings on the manifold. Do
not touch the heater without protective wear. Failure to do so can
result in serious burn and/or injuries.
6.3 Function
Resistance
All hydrous solvents (Media,
organic acid and base)
*Maximum heater setting value
90 °C
Supply Voltage
24 VDC
Power consumption
15 W
*Displayed temperature may not reflect the actual dispensed temperature.