Section 8 Trigger Recording & Interval Recording
In es8, you can choose trigger recording or interval recording as well as manual recording by key operation.
Choosing the recording mode can be done in <Mode> of <RECCOND MENU>.
8.1. Trigger Recording
In the trigger recording mode, recording can be performed by a pre-trigger only or by a post-trigger.
Repetition recording is also available.
The recording action as shown n the figure below is a repeated designated count (Repeat Count). A recording of 1 count only is also
available
Using pre-trigger together
Using post-trigger together
Before recording
by
trigger action, press
[STANDBY] to put the
system in the recording
stand-by (REC STANDBY)
status after the trigger
settings. It is not
required to put the
system in recording
stand-by status in the
case of external trigger
without
pre-trigger.
Stop
Pre-trigger
Recording Start Condition
is satisfied:
Level trigger
External trigger
Recording Stop Condition
is satisfied:
Level trigger
External trigger
The condition that was satisfied
previously is available when
multiple conditions are being set.
When CSV format is chosen as
recording format and pre-trigger is
used, the stop condition is
available only for recording the
time, and stop will be delayed for a
few seconds of the pre-trigger.
However, the time of the data file
is the time that is recorded
actually.
Post-trigger
Stop
Start
Start
Before recording by
trigger action, press
[STANDBY] to put the
system in the recording
stand-by (REC
STANDBY) status after
the trigger settings. It
is not required to put
the system in recording
stand-by status in the
case of external trigger
without
pre-trigger.
The condition that was satisfied
previously is available when
multiple conditions are being set.
Recording Start Condition
is satisfied:
Level trigger
External trigger
Recording Stop
Condition is satisfied:
Level trigger
External trigger
<Start condition>
Level trigger: The trigger is a change in level in a specified channel.
External trigger: If the signal input to the external trigger pin of the
Input connector is low, recording will start. The interval until the next
recording starts should be 5 sec or more. The signal is TTL level (active
low).
It is not required to put the system in recording-standby status in case
of the external trigger without the pre-trigger. Recording starts
immediately when the Low level signal is inputted.
<Stop condition>
External trigger: If the signal input to the external trigger pin of the
Input connector is low, recording will stop. The signal is TTL level
(active low), and Open is possible for High level.
Recording time: The system records data during the specified time
after starting.
Page 40
Summary of Contents for es8
Page 12: ...Note Page 4...
Page 15: ...Section 2 Name Functions of Each Part Comparator Output Diagram Page 7...
Page 25: ...Section 3 Before Recording Note Page 17...
Page 36: ...Page 28...
Page 41: ...Section 6 Detailed Recording Setting Note Page 33...
Page 42: ...Note Page 34...
Page 47: ...Page 39...
Page 53: ...Section 9 Comparator Function Note Page 45...
Page 57: ...Section 11 Saving Loading Settings Note Page 49...
Page 59: ...Section 11 Manual Calibration Note Page 51...
Page 61: ...Section 12 MISC MENU Note Page 53...
Page 63: ...Section 13 Specifications Page 55...
Page 65: ...Section 13 Specifications Page 57...
Page 67: ...Section 13 Specifications Note Page 59...
Page 68: ...Note...