409-10100
19 of 59
Rev C
Touch the next Sensitivity arrow or the right arrow icon to move to the next task.
4.7. Peak Force (PF) and Work Index (WI) Sensitivity
Touch the
Up
and
Down
arrows to change the sensitivity settings of the Peak Force and Work Index. Press
Default to return the setting to the factory default.
Default sensitivity settings typically work good for terminals and wire combinations that meet the minimum Head
Room criteria of 35% or greater. If the CQM II Fails crimps that you determine to be Good crimps, then you may
want to adjust the sensitivity of the analysis method that is causing this problem. In this case, adjust the
sensitivity to be less sensitive by a few points, for example 3.0 to 3.5 (the higher the number the less sensitive).
If the CQM II is not detecting the crimp failures that you expect it to detect, then you may want to adjust the
sensitivity of the various analysis methods to be more sensitive by a few points, for example from 3.0 to 2.5.
Touch the next Sensitivity arrow or the right arrow icon to move to the next task.