409-10100
11 of 59
Rev C
A. CQM Settings -- Setup Tab
Touch the CQM Settings icon to bring up the CQM Settings screen shown below.
For the Custom selection, the four outputs can be configured to interface to the intended host machine,
including the Crimp Enable output.
A non-terminated cable is provided for connection to the host machine. Refer to installation documentation
for specifics.
B. CQM Settings -- Position Sensor Tab
Choose the Position Sensor tab to select the position sensor that is installed on your terminating machine.
Selections are: Linear Encoder, Encoder (30mm) (for 30 mm stroke machines), Analog Height sensor (original
CQM position sensor. Trigger (for force only systems) and CQM Applicator (for those customers who may still
have an early TE applicator with CQM sensors integrated). For the Analog Height sensor and TE applicators
with CQM sensors, the 6 coefficients must be entered exactly as they are printed on the associated tag and
an optional cable is required for connection.
For Force Only applications that use a trigger sensor, normally Custom host machine types, the CQM II does
not use all of the available analysis methods. Only FFT and peak force are available