D. CQM Settings -- Sensor Calibration Tab
If you have the Analog Height sensor, then you must calibrate it. Select the Sensor Calibration and follow the
instructions on the display and enter the Low and High voltages that you measured based on the switch
settings of the A/D Calibration Switch. A TE A/D Calibration Switch and a digital volt meter are required to
perform this calibration.
E. CQM Settings -- Learn Tab
Choose the Learn tab to select the Learn settings. TE recommends using the default of 5-crimps to properly
learn the process. You can lower it to 3-crimps if you are confident in your process and the terminals you are
using. If you want the best analysis capable once you enter production, increasing the Learn crimps will
improve the statistical analysis of the crimp process that you are monitoring. .
During the Learn process you can choose to have each learned crimp ‘Accepted as Good’ so that you do not
have to acknowledge the CQM II. Select Auto Accept Good Learn Crimps. In all cases, during the Learning