24
・All specifications are subject to change without notice.
Instruction Manual
HWS
HWS HD
HWS ME
HWS-P
ITEMS/UNITS
MODEL
HWS1000
-3
HWS1000
-5
HWS1000
-6
HWS1000
-7
HWS1000
-12
HWS1000
-15
HWS1000
-24
HWS1000
-36
HWS1000
-48
HWS1000
-60
Input
Voltage Range
(*2)
V
AC85 - 265 or DC120 - 330
Frequency
(*2)
Hz
47 - 63
Power Factor (100/200VAC)(typ) (*1)
0.98 / 0.95
Efficiency (100/200VAC)(typ)
(*1)
%
71 / 73
76 / 78
79 / 81
80 / 82
82 / 85
83 / 85
85 / 87
85 / 88
86 / 88
85 / 88
Current (100/200VAC)(typ)
(*1)
A
9.6 / 5.0
13.5 / 7.0
Inrush Current (100/200VAC)(typ) (*3)
A
20 / 40
Leakage Current (100/240VAC) (*10) mA
1.2 max
Output
Nominal Voltage
VDC
3.3
5
6
7.5
12
15
24
36
48
60
Maximum Current
A
200
167
134
88
70
46
30.7
23
18.4
Maximum Peak Current
(*13)
A
−
160
100
80
58.5
39
29.2
23.4
Maximum Power
W
660
1000
1002
1005
1056
1050
1104
Maximum Peak Power
(*13)
W
−
1200
1404
Maximum Line Regulation
(*5) mV
20
36
48
60
96
144
192
240
Maximum Load Regulation
(*6) mV
40
60
100
120
150
300
360
Temperature Coefficient
Less than 0.02%/
℃
Maximum
Ripple & Noise (*4)
0 to +71
°
C mVp-p
120
150
200
400
-10 to 0
°
C mVp-p
160
180
240
500
600
Hold-up Time (typ)
(*9)
ms
20
Voltage Adjustable Range
VDC 2.64 - 3.96 4.0 - 6.0
4.8 - 7.2
6.0 - 9.0 9.6 - 14.4 12.0 - 18.0 19.2 - 28.8 28.8 - 43.2 38.4 - 52.8 48.0 - 66.0
Function
Over Current Protection
(*7)
A
>210.0
>175.3
>168.0
>105.0
>84.0
>61.4
>40.9
>30.6
>24.5
Over Voltage Protection
(*8) VDC 4.12 - 4.62 6.25 - 7.0 7.5 - 8.4 9.37 - 10.5 15.0 - 17.4 18.7 - 21.8 30.0 - 34.8 45.0 - 49.7 55.2 - 60.0 69.0 - 75.0
Remote Sensing
Possible
Remote ON/OFF Control
Possible
Parallel Operation
Possible
Series Operation
Possible
Monitoring Signal
PF (Open collector output)
Line DIP
Built to meet SEMI-F47 (200VAC line only)
Environment
Operating Temperature
(*11)
℃
-10 to +71 , start up -20 to +71
-10 to +40
℃
%
100
+50
℃
%
83.9
100
+71
℃
%
50
Storage Temperature
℃
-30 to +85
Operating Humidity
%
RH
10 - 90 (No Condensing)
Storage Humidity
%
RH
10 - 95 (No Condensing)
Vibration
At no operating, 10 - 55Hz (sweep for 1min.) 19.6m/s² constant, X, Y, Z 1hour each.
Shock (In package)
Less than 196.1m/s²
Cooling
Forced air by blower fan
Isolation
Withstand Voltage
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output-FG : 500VAC (300mA) (60V model 651VAC (390mA)), Output-CNT:100VAC (100mA) for 1min.
Isolation Resistance
More than 100M
Ω
Output - FG : 500VDC
More than 10M
Ω
Output - CNT 100VDC at 25
℃
and 70%RH
Standards
Safety Standards
(*12)
Approved by
UL60950-1, CSA C22.2 No60950-1, EN60950-1,EN50178. Built to meet DENAN.
PFHC
Built to meet IEC61000-3-2
EMI
Built to meet EN55011/EN55022-B, FCC-ClassB, VCCI-ClassB, CISPR-ClassB.
Immunity
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (max)
g
3200
Size (W x H x D)
mm
126.5 x 82 x 240 (Refer to outline drawing)
(*1) At Ta=25
℃
and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required,
input voltage range will be 100 - 240VAC (50/60Hz).
(*3) First in-rush current. Not applicable to the first 0.2ms in-rush current flowing into the power supply noise filter.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope :100MHz.
(
At 100uF electric capacitor and 0.47uF film capacitor on the test fixture board.)
(*5) 85 - 265VAC, constant load.
(*6) No load-full load, constant input voltage.
(*7) Constant current limit with automatic recovery. Over current condition for more than 5 seconds will cause the
output to shutdown.
Output current exceeding maximum rated output current for more then 10 seconds continuously will result to
output
shutdown.
(*8) OVP circuit will shut down output, manual reset (power cycle) or ON/OFF CNT signal reset.
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz), Ta=25
℃
.
(*11) Ratings - Derating at standard mounting.
-
Load (%) is percent of maximum output power or maximum output current, whichever is greater.
-
As for other mountings, refer to derating curve.
(*12) As for DENAN, built to meet at 100VAC.
(*13) Peak output current is less than 10 seconds, and duty 35% max.(200VAC Line only)
Please refer to "TDK-Lambda
EMC Filters" catalog.
●Recommended EMC Filter
RSEN-2020
HWS
1000
HWS1000 Specifications
(Read instruction manual carefully, before using the power supply unit.)