・All specifications are subject to change without notice.
Instruction Manual
HWS
HWS HD
HWS ME
HWS-P
Remote sensing required
① Connect +S terminal to + terminal of load with sensing wire
② Connect -S terminal to - terminal of load with sensing wires.
③ Connect CNT terminal to TOG terminal with wire.
④ Connect PV terminal to REF terminal with wire.
※ The accuracy of the output voltage will deteriorate when the
sensing terminals are opened.
※ In the following cases, the output is shut down.
When CNT and TOG is opened.
When PV and REF is opened.
Remote ON/OFF control required
① Remove standard attached connector, and use the harness
made by the customer and connect external signal to
between CNT and TOG terminal.
② TOG terminal is ground for CNT terminal.
In case this function is not used, please short between CNT
and TOG terminal.
PF signal output required
① PF signal is an open collector output, therefore
PF signal outputs is shown in circuit below.
② TOG terminal is ground for PF terminal.
HWS
1500
Load
Connector : (JST) S12B-PHDSS
Remove standard attached connector, and use the harness made by
the customer.
・Housing : (JST) PHDR-12VS
・Contact : (JST) SPHD-001T-P0.5
(3-7V model) 2− + of output, 4− - of output : should be connected
(12-60V model) 1−2, 3−4 : should be shorted
7−8:should be shorted
9:CNT
Should be connected to ON/OFF control signal.
10:TOG
Should be connected to Signal Ground.
*Please use wire for contact and crimping tool specified by maker.
M8 Bolts and nuts for connecting
to the load line
(These are not attached to the
product.)
NAME PLATE
M8 Bolts and nuts for connecting
to the load line
(These are not attached to the
product.)
Load
Connector : (JST) S12B-PHDSS
Remove standard attached connector, and use the harness made
by the customer.
・Housing : (JST) PHDR-12VS
・Contact : (JST) SPHD-001T-P0.5
(3-7V model) 2− + of output, 4− - of output : should be connected
(12-60V model) 1−2, 3−4 : should be shorted
7−8:should be shorted
11:PF
Should be connected to PF signal output
12:TOG
Should be connected to Signal Ground.
*Please use wire for contact and crimping tool specified by maker.
NAME PLATE
1
2
3
4
5
6
7
8
9
10
11
12
ON
ON
1
2
3
4
5
6
7
8
9
10
11
12
+ of output
− of output
Load
Connector :
(JST) S12B-PHDSS
Remove standard attached
connector, and use the harness
made by the customer.
・Housing :
(JST) PHDR-12VS
・Contact :
(JST) SPHD-001T-P0.5
2− + of load, 4− - of load
should be connected.
7−8, 9−10:should be shorted
*Please use wire for contact
and crimping tool specified by
maker.
M8 Bolts and nuts
for connecting to
the load line.
(These are not attached
to the product.)
NAME PLATE
1
2
3
+ of output
− of output
4
5
6
7
8
9
10
11
12
Red
Black
Yellow
Brown
Connecting circuit with CN01 or CN02 connector
● Connecting circuit with CN01 or CN02 connector
(3-7V model)
(12-60V model)
● Connecting circuit with CN01 or CN02 connector
(3-7V model)
(12-60V model)
1
3
5
7
9
11
2
4
6
8
10
12
PF signal output
To signal ground
− of output
+ of output
PF signal output
To signal ground
1
3
5
7
9
11
2
4
6
8
10
12