115
・All specifications are subject to change without notice.
Instruction Manual
HWS
HWS HD
HWS ME
HWS-P
FG
L3
L2
L1
Load
+
−
M8 Bolts and nuts for connecting
to the load line.
(These are not attached to the
product.)
Connector : (JST) S12B-PHDSS
Attached connector when shipping
・Housing : (JST) PHDR-12VS
・Contact : (JST) SPHD-001T-P0.5
2− + of output, 4− - of output are connected.
7−8, 9−10 are shorted
Conn
Remo
custo
・Hou
・Con
2− +
7−8
* Plea
NAME PLATE
・12-60V model
① CS terminal to +V terminal and -S terminal to
-V terminal with sensing wires.
② Connect CNT terminal to TOG terminal with wire.
③ Connect PV terminal to REF terminal with wire.
※
Please use attachment connector for each connection.
※ In the following cases, the output is shut down.
When CNT and TOG is opened.
When PV and REF is opened.
Basic Connection (Local sensing)
・3-7V model
① CS terminal to + terminal of output and
-S
terminal to - terminal of output with sensing wires.
② Connect CNT terminal to TOG terminal with wire.
③ Connect PV terminal to REF terminal with wire.
※
Please use attachment connector for each connection.
※ In the following cases, the output is shut down.
When CNT and TOG is opened.
When PV and REF is opened.
FG
L3
L2
L1
Load
+
−
M8 Bolts and nuts for connecting
to the load line.
(These are not attached to the
product.)
Connector : (JST) S12B-PHDSS
Attached connector when shipping
・Housing : (JST) PHDR-12VS
・Contact : (JST) SPHD-001T-P0.5
1−2, 3−4, 7−8, 9−10 are shorted.
Conn
Remo
custo
・Hou
・Con
2−
7−8
* Ple
NAME PLATE
1
3
5
7
9
11
2
4
6
8
10
12
Twist wire
Red
Black
Brown Yellow
Attached connector when shipping
FG
L3
L2
L1
Load
+
ー
ting
e
M8 Bolts and nuts for connecting
to the load line.
(These are not attached to the
product.)
Connector : (JST) S12B-PHDSS
Remove standard attached connector, and use the harness made by the
customer.
・Housing : (JST) PHDR-12VS
・Contact : (JST) SPHD-001T-P0.5
2− + of load, 4− - of load should be connected.
7−8, 9−10:should be shorted
* Please use wire for contact and crimping tool spectfied by maker.
NAME PLATE
Remote sensing required
① Connect +S terminal to + terminal of load with sensing
wire
② Connect -S terminal to - terminal of load with sensing
wires.
③ Connect CNT terminal to TOG terminal with wire.
④ Connect PV terminal to REF terminal with wire.
※ The accuracy of the output voltage will deteriorate when the
sensing terminals are opened.
※ In the following cases, the output is shut down.
When CNT and TOG is opened.
When PV and REF is opened.
1
3
5
7
9
11
2
4
6
8
10
12
− of output
+ of output
Red
Black
Brown Yellow
Attached connector when shipping
HWS
1800T
P79-132.indd 115
09.10.26 10:29:38 AM