14
・All specifications are subject to change without notice.
Instruction Manual
HWS
HWS HD
HWS ME
HWS-P
HWS80 Specifications
(Read instruction manual carefully, before using the power supply unit.)
ITEMS/UNITS
MODEL
HWS80-3
HWS80-5
HWS80-12
HWS80-15
HWS80-24
HWS80-48
Input
Voltage Range
(*2)
V
AC85 - 265 or DC120 - 370
Frequency
(*2)
Hz
47 - 63
Power Factor (100/200VAC)(typ) (*1)
0.98 / 0.90
0.99 / 0.95
Efficiency (100/200VAC)(typ)
(*1)
%
77 / 79
82 / 85
83 / 85
84 / 86
Current (100/200VAC)(typ)
(*1)
A
0.72 / 0.36
1.04 / 0.52
Inrush Current (100/200VAC)(typ) (*3)
A
14 / 28, Ta=25
℃
, cold start
Leakage Current
(*10) mA
Less than 0.5. (0.2 (typ) at 100VAC / 0.4 (typ) at 230VAC)
Output
Nominal Voltage
VDC
3.3
5
12
15
24
48
Maximum Current
A
16
6.7
5.4
3.4
1.7
Maximum Power
W
52.8
80
80.4
81
81.6
Maximum Line Regulation
(*5) mV
20
48
60
96
192
Maximum Load Regulation
(*6) mV
40
96
120
192
384
Temperature Coefficient
Less than 0.02% /
℃
Maximum Ripple & Noise (0≤Ta≤70
℃
) (*4) mVp-p
120
150
200
Maximum Ripple & Noise (
−
10≤Ta< 0
℃
) (*4) mVp-p
160
180
240
Hold-up Time (typ)
(*9)
ms
20ms
Voltage Adjustable Range
VDC
2.97 - 3.96
4.0 - 6.0
9.6 - 14.4
12.0 - 18.0
19.2 - 28.8
38.4 - 52.8
Function
Over Current Protection
(*7)
A
>16.8
>7.04
>5.67
>3.57
>1.79
Over Voltage Protection
(*8) VDC
4.13 - 4.95
6.25 - 7.25
15.0 - 17.4
18.8 - 21.8
30.0 - 34.8
55.2 - 64.8
Remote Sensing
Possible
Remote ON/OFF Control
Possible (/R Option)
Parallel Operation
-
Series Operation
Possible
Line DIP
Built to meet SEMI-F47 (200VAC Line only)
Environment
Operating Temperature
(*11)
℃
-10 to +70 (-10 to +50: 100%, +60: 60%, +70: 20%)
Storage Temperature
℃
-30 to +85
Operating Humidity
%
RH
30 - 90 (No dewdrop)
Storage Humidity
%
RH
10 - 95 (No dewdrop)
Vibration
At no operating, 10 - 55Hz (sweep for 1min)
19.6m/s² constant, X, Y, Z 1hour each.
Shock (In package)
Less than 196.1m/s²
Cooling
Convection cooling
Isolation
Withstand Voltage
Input - FG : 2kVAC (20mA), Input - Output : 3kVAC (20mA)
Output - FG : 500VAC (100mA) for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Output - FG : 500VDC
Standards
Safety Standards
(*12)
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1, EN50178 UL508 (with cover models only),
CSA C22.2 No.14-M95 (with cover models only) Built to meet DENAN
PFHC
Built to meet IEC61000-3-2
EMI
Built to meet EN55011/EN55022-B, FCC-B, VCCI-B
Immunity
Built to meet IEC61000-4-2(Level 2,3), -3(Level 3), -4(Level 3),
-5(Level 3,4), -6(Level 3), -8(Level 4), -11
Mechanical
Weight (typ)
g
450
Size (W x H x D)
mm
28 x 82 x 160 (Refer to outline drawing)
(*1) At 100/200VAC, Ta=25
℃
and maximum output power.
(*2) For cases where conformance to various safety specs (UL, CSA, EN) are required, to be described as 100 - 240VAC (50/60Hz).
(*3) Not applicable for the in-rush current to noise filter for less than 0.2ms.
(*4) Measure with JEITA RC-9131A probe, bandwidth of scope : 100MHz.
(*5) 85 - 265VAC , constant load.
(*6) No load-full load, constant input voltage.
(*7) Constant current limit and hiccup with automatic recovery. Not operate at over load or
dead short condition for more than 30 seconds.
(*8) OVP circuit will shutdown output, manual reset (re power on).
(*9) At 100/200VAC, nominal output voltage and maximum output current.
(*10) Measured by the each measuring method of UL, CSA, EN and DENAN (at 60Hz).
(*11) Ratings - Derating at standard mounting.
- Load (%) is percent of maximum output power or maximum output current, whichever is greater.
- As for other mountings, refer to derating curve.
(*12) As for DENAN, built to meet at 100VAC.
Please refer to "TDK-Lambda
EMC Filters" catalog.
●Recommended EMC Filter
RSEL-2002W
HWS
80
Summary of Contents for HWS?HWS