101
・All specifications are subject to change without notice.
Instruction Manual
HWS
HWS HD
HWS ME
HWS-P
3. Mounting Directions
Output Derating
Mounting directions are as follows.
Standard mounting method is (A). Methods (B), (C) and (D)
are also possible.
Mounting methods besides (A),(B),(C) and (D) (example :
(E) and (F)) are inhibited.
HWS1000 Output Derating
3, 5V
Ta(℃)
6-60V
Ta(℃)
LOAD(%)
A
B
C
D
−10 - +35
−10 - +35
100
100
100
100
40
50
100
100
100
100
71
71
50
50
50
50
100
80
60
40
20
0
−10
20
( )
Load(%)
40
50
60
71
0
3.5VModel
6,7,12,15,24,36,48,60VModel
Mounting A, B, C, D
Mounting Method Caution
(1) This Power supply unit is a forced air-cooling system
with a built-in fan.
(2) This power supply has ventilating holes on the front
and back panels.
Keep these areas freely more than 100mm from front
side and more than 50mm from rear side.
(3) Please note that ventilation will be worsened in a
dusty environment.
(4) Built-in fan is limited life part, which require periodic
replacement. (Replacement will be charged).
(5) The ambient temperature of this power supply is less
than 50mm from the center of a front side.
(6) The maximum allowable penetration of mounting
screw is 6mm.
(7) Recommended torque for mounting screw (M4) is
1.27N・m.
More than50mm
More than100mm
(Front)
(Rear)
(Top:HWS1000)
Fan motor
(A)Standard
Mounting
(B)
(C)
(D)
(F)Inhibit
(E)Inhibit
HWS
1000
ON
CNO1
VADJ
H
CNO2
FG
N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG
N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG
N〔AC〕L
ON
CNO1
VADJ
H
CNO2
FG
N〔A
C〕
L
P79-132.indd 101
09.10.26 10:29:28 AM
Summary of Contents for HWS?HWS