Door lock open or closed
Door lock open or closed
Sends 24VDC to relay switche
Sends 24VDC to relay switche
Sends 24VDC to pneumatic switch to drop blade
Sends 24VDC to pneumatic switch to drop blade
Sends 24VDC to saw cabinet door lock to unlock
Sends 24VDC to saw cabinet door lock to unlock
Sends power to AC-Tech relay
Sends power to AC-Tech relay
Triggers AC-Tech saw motor relay
Triggers AC-Tech saw motor relay
Sends 24VDC to outfeed pneumatic switch (clamp)
Sends 24VDC to outfeed pneumatic switch (clamp)
Sends 24VDC to outfeed pneumatic switch (unclamp)
Sends 24VDC to outfeed pneumatic switch (unclamp)
Sends 24VDC to infeed pneumatic switch (clamp)
Sends 24VDC to infeed pneumatic switch (clamp)
Sends 24VDC to infeed pneumatic switch (unclamp)
Sends 24VDC to infeed pneumatic switch (unclamp)
White I/O Modules
White I/O Modules
Red I/O Modules
Red I/O Modules
Signal to PMAC that “eye” sees a board
Signal to PMAC that “eye” sees a board
Not used
Not used
Not used
Not used
Sends signal from upper prox to PMAC
Sends signal from upper prox to PMAC
Sends signal from lower prox to PMAC
Sends signal from lower prox to PMAC
Signal to PMAC to start saw motor
Signal to PMAC to start saw motor
MC relay has power
MC relay has power
Sends signal to PMAC to Start Autocycle
Sends signal to PMAC to Start Autocycle
Sends signal to PMAC to Stop Cycle
Sends signal to PMAC to Stop Cycle
Indicates saw motor not turning
Indicates saw motor not turning
AT relay has power
AT relay has power
ES relay has power
ES relay has power
Saw head past 15/165 degrees
Saw head past 15/165 degrees