- 59 -
3. TROUBLESHOOTING GUIDE
(5)
407
35
: Pump motor thermosensor defective
AD input range abnormal
Automatically resets when the input returns to
normal.
①
Check the pump motor thermosensor for looseness. Connect securely.
②
Check the voltage between
CN2P-6
and
CN2P-17
on the pump motor inverter unit.
Repair the pump motor or wiring.
③
Replace the pump motor inverter unit.
(6)
410
73
: Rotation sensor defective
The A or B phase pulse is missing.
The A and B phase pulses are missing.
Automatically resets when the input returns to
normal.
410
74
: Rotation sensor defective
Abnormal bearing (Stall signals detected
continuously)
Automatically resets when the input returns to
normal.
①
Check the voltage between the pump motor inverter
unit (
CN2P-5, -16, -29
) and the speed sensor
Correct the wiring.
②
Check the pump motor slit board.
Repair the motor slit board.
③
Check the rotation sensor.
Repair the rotation sensor.
④
Replace the pump motor inverter unit.
(7)
412
06
: Lift potentiometer defective
Automatically resets when the input returns to
normal.
①
Check the lift potentiometer connector for looseness. Connect securely.
②
Check the harness between the pump motor inverter
unit (
CN2P-8, -20, -32
) and the lift potentiometer.
Correct the wiring.
③
Check the lift potentiometer.
Repair the lift potentiometer.
④
Replace the pump motor inverter unit.
Summary of Contents for FB-8 Series
Page 2: ......
Page 4: ......
Page 22: ......
Page 26: ......
Page 38: ...NOTE 1 BATTERY 12...
Page 40: ...14 Fig 2 1 Drive Motor Installation DRIVE UNIT DRIVE AXLE DRIVE MOTOR 2 MOTORS...
Page 92: ...NOTE 6 STEERING SYSTEM 66...
Page 106: ...NOTE 6 STEERING SYSTEM 80...
Page 126: ...100 Remove the oil seal from the front cover Fig 7 28 7 HYDRAULIC SYSTEM...
Page 150: ...NOTE 8 LOAD HANDLING SYSTEM 124...
Page 234: ...72 3 TROUBLESHOOTING GUIDE NOTE...
Page 246: ...84 6 ELECTRIC WIRING NOTE...
Page 258: ......
Page 259: ...n m o m Z C F H d o H H M 0 M Z 0 m O m C O R P O R A T I O N T C M...