- 26 -
2. ELECTRICAL PARTS AND PROCEDURES FOR CHECKING
2.2.13 CM CONTACTOR
The CM contactor is used for the on-board battery charger. During charging, 3-phase AC is flowing
through the contactor to open the contact B, thus shutting off the control circuit power supply for the
controllers and other devices. Under normal conditions, it opens the 3-phase contacts to prevent the
charge current from flowing.
Applicable truck
model
CM contactor
Thermal relay
setting
Input voltage
Thermal relay
setting range
FB10-8
FB15-8
FB18-8
281E2-62661
13A
3 ø 50/60Hz 380/390 V
430/440 V
9 to 13 A
FB20-8
FB25-8
281E2-62651
18A
12 to 18 A
FB25-8LB
FB25-8V
FB30-8
FB30-8V
FB35-8S
281U2-62661
26A
18 to 26 A
Checking procedure
(1) Checking coil resistance
Measure the resistance between points “a” and “b”.
The resistance should be 0.1 to 0.3 kΩ.
(2) Checking for continuity of contact B
Measure the resistance between points “c” and “d”.
There should be no continuity while the button “e” at the center
is being pressed.
Coil
3-phase AC
Contact B
Summary of Contents for FB-8 Series
Page 2: ......
Page 4: ......
Page 22: ......
Page 26: ......
Page 38: ...NOTE 1 BATTERY 12...
Page 40: ...14 Fig 2 1 Drive Motor Installation DRIVE UNIT DRIVE AXLE DRIVE MOTOR 2 MOTORS...
Page 92: ...NOTE 6 STEERING SYSTEM 66...
Page 106: ...NOTE 6 STEERING SYSTEM 80...
Page 126: ...100 Remove the oil seal from the front cover Fig 7 28 7 HYDRAULIC SYSTEM...
Page 150: ...NOTE 8 LOAD HANDLING SYSTEM 124...
Page 234: ...72 3 TROUBLESHOOTING GUIDE NOTE...
Page 246: ...84 6 ELECTRIC WIRING NOTE...
Page 258: ......
Page 259: ...n m o m Z C F H d o H H M 0 M Z 0 m O m C O R P O R A T I O N T C M...