- 32 -
2. ELECTRICAL PARTS AND PROCEDURES FOR CHECKING
2.2.19 F/R SWITCH
Checking procedure
Measure the resistance between terminals with the multimeter in the resistance range (minimum
range).
Standard value
IG1 (GND)
|
VF (Inverter CN1-8)
①
0 Ω for F
②
∞ for positions
other than F
IG1 (GND)
|
VR (Inverter CN1-21)
①
0 Ω for R
②
∞ for positions
other than R
Terminal position