<ESC>a<n>
select justification and centering mode
<n> =
0
➵
left justification
1
➵
centered
2
➵
right justification
3
➵
left and right justification
✔
✔
<ESC>A<n>
Set line feed to n/60 inch (<n> = 1 - 127)
✔
✔
✔
<ESC>A<n>
Set n/72 inch line feed (<n> = 1 - 85)
✔
✔
<ESC>b<m><0>
clear all tab settings
✔
✔
<ESC>b<m><n><0>
set vertical tabs in channels
<m> = 0 - 3
<n> = 1 - 154
✔
✔
✔
✔
<ESC>B<0>
reset all vertical tab stops
✔
✔
<ESC>B<n1>..<n16><0>
set vertical tab stops
✔
✔
<ESC>B<n1>..<n64><0>
set vertical tab stops
✔
✔
✔
✔
<ESC>C<0><n>
set form length in inches (<n> = 1 - 22)
✔
✔
✔
✔
<ESC>C<n>
set form length in lines (<n> = 1 - 127)
✔
<ESC>d<n1><n2>
set relative horizontal step
Formula:
n = relative print position
<n2> = INT (n/256)
<n1> = n MOD 256
✔
✔
✔
✔
<ESC>D<0>
clear all horizontal tab stops
✔
✔
✔
✔
<ESC>D<n1>..<n32><0>
set horizontal tab stops
✔
✔
✔
✔
<ESC>E
emphasized mode ON
✔
✔
✔
✔
<ESC>F
emphasized mode OFF
✔
<ESC>g
set character density to 15 cpi
✔
✔
✔
<ESC>G
double strike print mode ON
✔
<ESC>G
print quality NLQ ON
✔
<ESC>H
print quality NLQ OFF
✔
✔
✔
<ESC>H
reset double strike print mode
✔
<ESC>I<1>
characters 0 - 31 and 128 - 159 transparent
✔
<ESC>I<0>
downloaded or international characters
✔
✔
<ESC>I<n>
print mode selection
<n>
0 DPQ
DPQ 10 cpi
1 DPQ
–
2 NLQ
NLQ/LQ 10 cpi
3 NLQ
NLQ/LQ Prop.
4 DPQ (DLL)
DPQ 10 cpi (DLL)
5 DPQ (DLL)
–
6 NLQ (DLL)
NLQ/LQ 10 cpi (DLL)
7 NLQ (DLL)
NLQ/LQ Prop. (DLL)
8 –
DPQ 12 cpi
10 –
NLQ/LQ 12 cpi
IBM
IBM
Epson
Epson
IBM-
MTPL
Propr.
Propr.
FX850
LQ850+
AGM
Code
Function
X/XL
X24/XL24 FX1050
List of available control codes