Pro Pump Controller (ProCon-100)
Rev3.6
2023/07/17
65/70
Copyright
©
2023 by TAEHA CORP. All Rights Reserved
5
$,O,!,# - normal
$,O,?,Data,# - abnormal
Response shot stop command
ex) $,O,!,# (normal) // $,O,?,0,# (BUSY)
① $ : STX (
command start)
②
O : Shot stop command
③ ! :
Normal reception complete
? : Abnormal reception
④ Data
<Abnormal reception status>
- 0 : Busy status
- 1 : Data format error
- 2 : Data input range error
⑤ # :
ETX (command complete)
Procon-100
➔
host controller
(RESPONSE)
6
$,T,Data,#
Shot command after channel change
ex) $,T,1,#
① $ : STX (
command start)
②
T : Shot command after channel change
③ Data
- Channel number : 1 (channel 1)
③ # :
ETX (Command complete)
Host controller
➔
Procon-100
(REQUST)
* The
‘
RESPONSE
’
operation is
the same as the shot
command.
7
$,H,Data,#
Change channel command
ex) $,H,1,#
① $ : STX (
command start)
② H :
change channel command
③ Data
- Channel number : 1 (channel 1)
③ # :
ETX (command complete)
Host controller
➔
Procon-100
(REQUST)
8
$,H,!,# - normal
$,H,?,Data,# - abnormal
Response shot stop command
ex) $,H,!,# (normal) // $,H,?,0,# (BUSY)
① $ : STX (
command start)
②
O : Change channel command
③ ! :
Normal reception complete
? : Abnormal reception
④ Data
<Abnormal reception status>
- 0 : Busy status
- 1 : Data format error
- 2 : Data input range error
⑤ # :
ETX (command complete)
Procon-100
➔
host controller
(RESPONSE)