5.5.5
Compensation Setting
Figure 23. Compensation Setting
-
Select the Next button in suck back speed screen to display the screen for the compensation.
-
Displays the ratio adjustment.(0~150%) The number of rotations increases or decreases
according to the setting rate.
-
The default value is 100% and works at a 1:1 ratio. Enter a value more than 100 to increase
the number of rotations or less than 100 to decrease.
-
By selecting the Up/Down key or Data Box, you can set the value through the key pad screen.
-
If you adjust the value at random, the dispensing amount changes. Do not make changes
except administrator.
-
If you want to go to the next setting menu, click
‘Next’ button
.
-
If you want to go to the main screen
, click ‘Exit’ button
.
Caution
If compensation value is changed, the amount of shot is changed and not
guaranteed to be quantified.