5.9.2
Configuration command
: using COMMAND - P
➔
parameter setting / R
➔
Request parameter data
<Description of parameter transfer data>
- Channel : Channel data (1 ~ 15)
➔
ex) channel
2 : ‘2’
- Mode : Channel mode (0:Time / 1:Steady / 2:Metering)
ex) Time Mode : ‘0’
- Shot Time : Shot Time data (0~999999, unit : 0.01 sec)
➔
ex) 1sec : ‘100’
- Metering Value : Metering data (4~30000, unit : 0.1mg)
➔
ex) 50mg : ‘500’
- Shot Speed : Shot Speed data (0~1200, unit : 0.1rpm)
➔
ex) 50rpm :
‘
500
’
- Suck Back Time : Suck Back Time data (0~999999, unit : 0.01 sec)
➔
ex) 1
sec : ‘100’
- Suck Back Speed : Suck Back Speed data (0~1200, unit : 0.1rpm)
➔
ex) 5rpm :
‘
50
’
- Compensation : Compensation data (50~150, unit : 1%)
➔
ex) 100% :
‘1
00
’
Table 16. Parameter setting command
No.
Command
Action
Send and receive
1
$,P,Data,#
Parameter setting request
ex) $,P,1,2,150,150,50,100,50,100,#
① $ : STX (
Command start)
② P :
Parameter transfer command
③ Data
- Channel : 1 (Channel 1)
- Mode : 2 (MODE 2 /METERING)
- Shot Time : 150 (1.5Sec)
- Metering Value : 150 (15.0mg)
- Shot Speed : 50 (50RPM)
- Suck Back Time : 10 (1.0Sec)
- Suck Back Speed : 50 (50rpm)
- Compensation : 100 (100%)
④ # :
ETX (Command complete)
Host controller
➔
Procon-100
(REQUST)
2
$,P,!,# - normal
$,P,?,Data,# - abnormal
Whether to send parameters
ex) $,P,!,# (Normal) // $,P,?,0,# (Busy)
① $ : STX (
Command start)
② P :
Parameter transfer command
③ ! :
Normal reception complete
? : Abnormal reception
④
Data
<Abnormal reception condition>
- 0 : Busy status
- 1 : Data format error
- 2 : Data input range error
⑤ # :
ETX (Command complete)
Procon-100
➔
host controller
(RESPONSE)