72
TimeProvider 2300/2700 User’s Guide
098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
show bridge-time
Displays the bridging time that is used to allow the frequency servo to coast through
short periods when the system does not have qualified reference. The bridging time
is in seconds.
Command Syntax:
show bridge-time
Example:
TP2700> show bridge-time
Response:
Bridging Time : 900
Remarks:
If the system has not qualified a time or frequency reference within the
specified bridging time the system transitions into holdover mode of operation.
Level :
User, Config, and Admin
set bridge-time
Provisions the amount of time, in seconds, the system remains in bridging mode
before transitioning into the holdover mode of operation. The bridge-time applies to
both clock-timing loop and clock-frequency.
Command Syntax:
set bridge-time <bridge-time-value>
Example:
TP2700> set bridge-time 1000
Level :
Config and Admin
Note:
Updates to the bridging-time value are only used at the start of
the next bridging event. Any changes to this value while the unit is in
bridging mode will not be implemented until the next bridging event.