TimeProvider 2300/2700 CLI Command Set
Command User Levels
The TimeProvider 2300/2700 provides a hierarchy of CLI command user levels that
permit an increasing level of access to system parameters. This allows the system
administrator to add users who can only view but not change system parameters
and users who can view
and
change system parameters.
The users assigned to each security level have access options available as follows:
Level 1 - user class, with read-only rights
Level 2 - config user class, with read-write rights
Level 3 - administrator user class, with read-write rights and can also configure
users and upgrade firmware
TimeProvider 2300/2700 CLI Command Set
This section provides an alphabetical listing and details of all CLI commands.
show alarm
Displays the system's standing (active) alarms and events.
Command Syntax:
show {alarm | event}
Example 1:
TP2700> show alarm
Response 1:
--------------------------------------------------------------------------------
|ID |Severity|Date-Time |Descriptions |
|---|--------|-------------------|---------------------------------------------|
|111|minor |2013-05-09 17:14:49|Ethernet port ETH2 link down |
--------------------------------------------------------------------------------
Example 2:
TP2700> show event
Response 2: