DOC 6511_Release K
ATS-6511A/B/C Users Guide
98
Thus, if the PPS input is provided on input 3 of the 4393A card installed in slot 4 it will be
identified as 'Ch43' on the ptdraw port.
Syntax
: ptdraw_port
Command Example:
ATS-6511>ptdraw_port
To end this session and return to the command port type
quit
and press enter.
See also:
ptdavg, ptdavg_port
Quit:
Description:
Terminates the current command port connection
Syntax
: quit
Command Example:
ATS-6511>quit
Reboot:
Description:
Reboots the ATS-6511.
By default the system will perform a warm reboot in which the outputs of the system and
current settings will be preserved during the reboot process. Specifying a cold reboot will
reset the system settings to their saved values and perform a complete reset of the hardware
which will result is a loss of output signals.
Syntax
: reboot [--cold]
Command Example:
ATS-6511>reboot
Reference (6511B/C):
Description
Select the preferred holdover reference source. The holdover reference is used
as frequency reference when fiber signals are lost. If the preferred reference source is
unusable, another usable reference source will automatically be selected on holdover entry.
The priority of selection is external, internal, then OCXO.
An alarm will be raised if the preferred source is not usable at any time. If you do not have
an external or internal holdover reference source, select OCXO to avoid the alarm
condition.
Syntax
: reference (external | ocxo)
Summary of Contents for ATS-6511A