DOC 6511_Release K
ATS-6511A/B/C Users Guide
95
pulse width has a minimum value of 5e-8 seconds and must not exceed half the value given
for the period (i.e. < 50% duty cycle).
Configuration of a specific output is stored on the system itself so that replacement modules
will automatically be configured with the correct output format. However, moving the
output module to a different slot causes the system to configure the module with the default
output format until reconfigured by the user.
See also: nasa36, irig, save
Usage: pps SLOT PORT PERIOD WIDTH
SLOT slot number of the card
PORT port number of the output
PERIOD period of pulse in seconds(max of 1, min of 1e-7)
WIDTH pulse width in seconds (minimum of 5e-8)
Command Examples:
ATS-6511>pps 1 2 1e-6 5e-7
Query:
ATS-6511> settings hardware:slots:1
[tsc4373]
[ports]
[1]
[pps_period] 1
[pps_width] 1.000000000000000e-04
[type] pps
[2]
[pps_period] 1.000000000000000e-06
[pps_width] 5.000000000000000e-07
[type] pps
[3]
[format] B
[signal_word] 0
[type] irig
[4]
[format] B
[signal_word] 0
[type] irig
See also:
nasa36, irig, save
Prompt:
Description:
Adjust command prompt settings or turn the prompt off. The prompt given
on the command port (port 1700) can be modified (or disabled) to aid in distinguishing
individual systems where more than one system may be present on a network. If the –
“default" option is specified the prompt will be modified for all new connections, otherwise
the prompt will only be modified for the current connection.
Syntax
: prompt –text(text) –enable(0|1) –default
text Specify PROMPT_TEXT for the prompt