DOC 6511_Release K
ATS-6511A/B/C Users Guide
67
[status] good
[power] enabled
[type] 4394A
[2-4]
Same as slot 1 for the card installed
[5]
[type] empty
Indicates a card is not installed.
[6]
[type] empty
[warmstartable] true
Unit has enough data to warmstart
[power]
Power Supply Information
[numsupplies] 2
# of Supplies Operating
[supplies]
[1]
Left Power Supply
[status] good
Current Status
[type] 4385A
Model #
[2]
Right Power Supply
[status] good
Same as Supply #1
[type] 4385A
[temperature] 30
Internal Temperature ºC
[health]
Operating Status Information
[clock_wander]
Clock Issues.
[active] false
Active = True for current alarm
[cleared]
When the alarm condition cleared
[what] Clock wander is less than 100.000000ns
What cleared
[when] 1998-01-01-00:06:49.651
When it cleared
[occurrences] 1
# of times the alarm has occurred
[set]
When the alarm happened
[what] Clock wander exceeded 100.000000ns
What happened
[when] 1998-01-01-00:06:47.534
When it occurred
[fan]
Fan Issues
[1]
[active] false
[occurrences] 0
[2]
[active] false
[occurrences] 0
[fiber_signal_present]
Fiber Issues
[active] false
[cleared]
[what] Fiber signal is present
[when] 2011-06-09-21:26:38.331
[occurrences] 1
[set]
[what] Fiber signal is missing
Note: This is the date when the unit is first
[when] 1998-01-01-00:02:31.457
powered up - the date/time has not been set.
[firmware_version_mismatch]
[active] false
[occurrences] 0
[hardware_internal]
Internal Clock Issues
[active] false
[occurrences] 0
[holdover_ref_comm_error]
[active] false
[occurrences] 0
[holdover_ref_missing]
[active] false
[occurrences] 0
[holdover_ref_unlocked]
[active] false